CmdGain2 ( Command Gain 2) f323

Type: Float, NV Parameter

 

Units, Range: 

BlkType = 0 Amperes/Volt

ebd_ebd25.gif

BlkType = 1 KRPM/Volt

ebd_ebd26.gif

BlkType = 2 Not Applicable

(see PulsesIn, PulsesOut)

BlkType = 4 Amperes/kHz

ebd_ebd27.gif

BlkType = 5 KRPM/kHz

ebd_ebd28.gif

BlkType = 8 Not Applicable

Not Applicable

 

 

Default: Parameter value set before last NVSAVE. Powering up an unconfigured drive sets this parameter to 0.0.

 

Purpose: CmdGain2 sets the scale factor of the analog input when a BDIO Input that has been mapped to the CmdGain2 function is asserted.

 

Guidelines: CmdGain2 is a floating point variable that sets the command gain:

 On the analog input (voltage from J4-1 to J4-2) for BlkType's:

  0 (Analog torque block), and

  1 (Analog velocity block).

 On encoder input frequency for BlkType's:

  4 (EncFreq Torque), and

  5 (EncFreq Velocity).