Type: Float, Status Variable, Read-Only.
Units: RPM
Range: -30,000 to +30,000
Purpose: Velocity is VelFB passed through a 3.5 Hz low pass filter.
Guidelines: When the measured velocity exceeds Velocity's range Velocity's value will be incorrect. See VelFB for an instantaneous indication of measured velocity that is accurate to higher speeds.